Insulation Resistance Tester HY2010
The instrument is with a variety of voltage output level (500V,1000V,2500V,5000V), high capacity, strong anti-interference, the pointer and digital synchronous display, AC-DC dual-use, simple operation, automatic calculation of various insulation index (absorption ratio, polarization index). All measured characteristics have the anti-power-down function . It is the ideal tester for insulation resistance like transformer, mutual inductor, electric generator, high voltage motor, power capacitor, power cable, and arrester.
1. There are a variety of output voltages (500V, 1000V,2500V, 5000V). Resistance range measuring range up to 0 ~ 200GΩ. Resistance measuring range can be automatically converted, and have the corresponding instructions.
2. Insulation resistance is simultaneously displayed in two ways: change range of insulation resistance can be easily observed by mechanical pointer; digital display has measurement accurate results.
3. With embedded and real-time operation of industrial microcomputer software system, high degree of automation and anti-interference ability, equipment can be automatically calculated absorption ratio and the polarization index, without human intervention.
4. All measurement results have anti-power-down function. It can store 19 consecutive measurements.
5. The built-in residual high-voltage discharge circuit can automatically release the residual pressure to the device under test after the test is completed.
6. Suitable for AC and DC. Rechargeable battery and AC adapter are configured.
7. Meter with portable design for easy field operation.
8. High voltage short circuit current ≥ 3mA
(Temperature, humidity: 23±5℃, 45~75%RH)
Model | HY2010 | ||||
Output Voltage | 500V DC | 1000V DC | 2500V DC | 5000V DC | |
Accuracy | Temperature | 23℃±5℃ | |||
Insulation Resistance | 0~20GΩ ±5% | 0~40GΩ ±5% | 0~99GΩ ±5% | 0~99GΩ ±5% | |
≥100 GΩ ±10% | |||||
Output Voltage | 4MΩ~20GΩ -5%~+10% | 8MΩ~40GΩ -5%~+10% | 20MΩ~100GΩ -5%~+10% | 40MΩ~200GΩ -5%~+10% | |
Short Circuit Current | ≥3mA | ||||
Working Power Supply | 8pcs AA alkaline batteries(8pcs AA rechargeable battery, charging adapter) | ||||
Working Temperature and Humidity | 0℃~40℃,maximum relative humidity 80% | ||||
Storage Temperature and Humidity | -10℃~60℃,maximum relative humidity 90% | ||||
Insulating Property | Insulation resistance between circuit and housing≥50MΩ | ||||
Withstand Voltage | Apply 3kv between tester circuit and housing, 50Hz sine AC voltage,last for one minute,no breakdown or flashover | ||||
Size | 230mm×190mm×90mm (L×W×H) | ||||
Weight | 2kg | ||||
Accessory | A set of one plug test lead, manual, Certificate of Approval, Charging adapter(C type) |