Battery Charger & Discharger HYBT-701
Battery Charger & Discharger HYBT-701 is special equipment for activation of VRLA (hereinafter referred as storage battery) with bad capacity caused by plate sulfuration crystallization. It possesses the functions of “activation” 、“check discharge” and “automatic charging” and etc. This equipment adopts current advanced testing technology theory, and it has obtained a series of breakthrough in research and application of new technology, new parts, new material and new technics.
1. Activation function:
Set up activation cycling, charge and discharge time of single activation, protective voltage and other parameters before activation, the instrument would operate activation function automatically
2. Check discharge function:
The tester could carry out discharge function automatically. When the battery reaches pre-defined final conditions or manually final operation could stop discharge test.
3. Charge function:
The instrument would operate charge function automatically, and display the data of charge current、battery charged capacity、battery voltage、charge time and etc, when the battery reaches pre-defined final charge condition or manually final operation could stop charge.
4. Real-time data memory:
Large data memory. Save 10 groups of activation data、10 groups of check discharge test data、10 groups of charge test data.
5. Data upload and export:
The test data could be uploaded to PC by 232 serial port, and could also be exported to U disc for save.
6. Automatic protection function:
When detecting battery is abnormal、working of activator is abnormal during test, the activator would stop the test automatically in order to protect the battery.
7. The activator adopts the design integrating monitoring part with power part.
8. Humanized operation interface, simple operation, clear flow, and each operation could have English cue.
9. Sea of blue high-brightness large LCD with clear and nice display effect.
10. Powerful functions of upper computer data management software, friendly interface, which could offer data management, statistics of report forms, automatic creation of test report and etc.
Measurement type of cell voltage | 2V/6V/12V |
Measurement range of cell voltage | 2V:0~3V; 6V: 4-8V; 12V:4-15V |
Resolution of cell voltage | 2V: 0.001V, 6V: 0.01V, 12V:0.01V |
Voltage testing accuracy | 0.5% |
Working range of charge and discharge current | 2A~100A |
Control accuracy of charge and discharge current | 0.1A |
Current testing accuracy | 1% |
Battery capacity check range | 2V:20-1000Ah; 6V:20-200Ah; 12V:20-300Ah; |
Working voltage | AC 220±15% |
Communication mode | RS232 communication and USB communication |
Cooling mode | Refrigeration by blasting |
Working environment | Temperature: 0℃~40℃ Humidity: 20%~80%RH |
Storage condition | -20℃~70℃ package and storage |
Display mode | LCD with high-brightness |
External dimensions(w×h×l) | 450mm×190mm×585mm |
Weight | 11kg |
Carrying method | Portable type, with roller movement |
Instrument parameter setting range:
Battery type | Charge/discharge current | Charge/discharge time | Min final voltage of discharge | Max limit voltage of charge |
2V | 2~100A | 00:01~99:59 | 1.65V | 2.50V |
Activation cycling | 1~8 | Charge/discharge time of | 00:01~19:59 | |
6V | 2~20A | 00:01~99:59 | 4V | 7.8V |
Activation cycling | 1~8 | Charge/discharge time of | 00:01~19:59 | |
12V | 2A~30A | 00:01~99:59 | 8V | 15V |
Activation cycling | 1~8 | Charge/discharge time of | 00:01~19:59 |
-